Equipment
PPMS
- Temperature: 50 mK – 4 K (With dilution cooler *)
- 1.8 K – 400 K (Conventional Mode);
- Characterization types: ETO (electrical measurement), Specific Heat;
- Magnetic field: 0 to ± 14 T;
- Sample size: ≤ 8mm
- ≤ 3 mm (for specific heat).
1260A – Solartron Analytical
- Dielectric interface module available: 10 μHz to 32 MHz, ± 40 V
- Impedance: 100 Ω to > 100 TΩ (1014Ω)
- Capacitance: 1 pF to >0.1 F
- Maximum DC voltage: ± 40.95 V
- Maximum current: ± 100 mA
- Maximum resolution: 10 mV / 200 μA
- FRA: 10 μHz to 32 MHz
Hall effect measurement
- Sample size: ≤ 12mm x 3mm x 12mm (W x H x D);
- Up to 6 electrical contacts;
- Van der Paul measure;
- Measured by Hall Bar;
- Temperature: 80 K (with liquid nitrogen)
- 300K
Current x voltage measurement (IxV)
- Parameter Analyzer
- 4 SMUs – 2x 4210-SMU and 2x 4200-PA
- Current source: Max 1A, Min 1fA
- Voltage source: Max 210V, Min 5 µV
- Available module: 4210 – CVU
- Frequency: 1 kHz to 10 MHz (fixed frequency)
- AC output: 10 mV to 100 mV RMS
- DC output: +/-30 VDC
Potentiostat / Galvanostat
- Electrode connections: 2, 3 and 4;
- Voltammetric, amperometric, galvanostatic and impedance measurements;
- Potential range: +/- 10V;
- Compliance voltage: +/- 30V;
- Maximum current: +/- 2 A;
- Current ranges: 1 A to 10 nA (100 pA with ECD module);
- PC interface: USB;
- Control software: NOVA;
- Extra modules: FRA32M and ECD;
- FRA / EIS: 10 μHz to 1 MHz.
μstat 4000P – Dropsens
- Multichannel with up to 4 working electrodes, sharing an auxiliary and a reference electrode;
- Voltammetric or amperometric measurements;
- Potential range: +/- 4V;
- Maximum current: +/- 80 Ma;
- Current ranges: 1 nA to 100 mA;
- PC interface: USB and Bluetooth®;
- Battery powered.
Potentiostat / Galvanostat / Impedance Analyzer
- Voltammetric, pulsed, amperometric, galvanostatic and impedance measurements;
- FRA / EIS: 10 μHz to 1 MHz;
- DC potential range: ± 10 V;
- Maximum current: ± 30 mA;
- Current range: 100 pA to 10 mA;
- Interface for PC and smartphone: Bluetooth® or USB connection
Impedance Analyzer
- Modules: MFRA 1MHz, MREF, MAT 1MHz;
- Maximum DC voltage: ± 8 V;
- Maximum current: ± 100 mA;
- Maximum resolution: 1 μV;
- FRA: 10 μHz to 1 MHz;
- PC interface: 100BASE-T Ethernet.
Equipment
PPMS
- Temperature: 50 mK – 4 K (With dilution cooler *)
- 1.8 K – 400 K (Conventional Mode);
- Characterization types: ETO (electrical measurement), Specific Heat;
- Magnetic field: 0 to ± 14 T;
- Sample size: ≤ 8mm
- ≤ 3 mm (for specific heat).
1260A – Solartron Analytical
- Dielectric interface module available: 10 μHz to 32 MHz, ± 40 V
- Impedance: 100 Ω to > 100 TΩ (1014Ω)
- Capacitance: 1 pF to >0.1 F
- Maximum DC voltage: ± 40.95 V
- Maximum current: ± 100 mA
- Maximum resolution: 10 mV / 200 μA
- FRA: 10 μHz to 32 MHz
Hall effect measurement
- Sample size: ≤ 12mm x 3mm x 12mm (W x H x D);
- Up to 6 electrical contacts;
- Van der Paul measure;
- Measured by Hall Bar;
- Temperature: 80 K (with liquid nitrogen)
- 300K
Current x voltage measurement (IxV)
- Parameter Analyzer
- 4 SMUs – 2x 4210-SMU and 2x 4200-PA
- Current source: Max 1A, Min 1fA
- Voltage source: Max 210V, Min 5 µV
- Available module: 4210 – CVU
- Frequency: 1 kHz to 10 MHz (fixed frequency)
- AC output: 10 mV to 100 mV RMS
- DC output: +/-30 VDC
Potentiostat / Galvanostat
- Electrode connections: 2, 3 and 4;
- Voltammetric, amperometric, galvanostatic and impedance measurements;
- Potential range: +/- 10V;
- Compliance voltage: +/- 30V;
- Maximum current: +/- 2 A;
- Current ranges: 1 A to 10 nA (100 pA with ECD module);
- PC interface: USB;
- Control software: NOVA;
- Extra modules: FRA32M and ECD;
- FRA / EIS: 10 μHz to 1 MHz.
μstat 4000P – Dropsens
- Multichannel with up to 4 working electrodes, sharing an auxiliary and a reference electrode;
- Voltammetric or amperometric measurements;
- Potential range: +/- 4V;
- Maximum current: +/- 80 Ma;
- Current ranges: 1 nA to 100 mA;
- PC interface: USB and Bluetooth®;
- Battery powered.
Potentiostat / Galvanostat / Impedance Analyzer
- Voltammetric, pulsed, amperometric, galvanostatic and impedance measurements;
- FRA / EIS: 10 μHz to 1 MHz;
- DC potential range: ± 10 V;
- Maximum current: ± 30 mA;
- Current range: 100 pA to 10 mA;
- Interface for PC and smartphone: Bluetooth® or USB connection
Impedance Analyzer
- Modules: MFRA 1MHz, MREF, MAT 1MHz;
- Maximum DC voltage: ± 8 V;
- Maximum current: ± 100 mA;
- Maximum resolution: 1 μV;
- FRA: 10 μHz to 1 MHz;
- PC interface: 100BASE-T Ethernet.